A fish cage net may remain in service for months without any obvious structural failure.
Then, during cleaning, harvesting, inspection, or replacement, the net is lifted—and suddenly:
An attachment loop breaks
A border rope tears
A seam opens
A corner fails
Several meshes rupture
This often surprises operators because the net appeared stable underwater.
But lifting creates a very different load condition from normal submerged service.
The key principle is:
A fish cage net that survives underwater loads may still fail when its wet mass and fouling load are concentrated into a limited number of lifting points.
During normal service, the net is supported by a combination of:
Frame attachments
Sinker systems
Water
Multiple border connections
Forces are distributed through a large structure.
During lifting, much more of the total load can be transferred through:
A few lifting loops
Upper borders
Corners
Temporary ropes
Crane or winch connections
This changes the load path dramatically.
Submerged objects experience buoyancy.
The net does not feel exactly the same underwater as it does when lifted into air.
Once the net leaves the water, buoyant support decreases.
The lifting system must then carry more of the actual mass.
This difference becomes much more important when the net is heavily fouled.
When lifted, the structure can carry:
Surface water
Water trapped between strands
Water inside folds
Water held by fouling
This temporary mass adds to the lifting load.
For PE netting, this should not simply be described as the polymer “absorbing water.”
Much of the added handling weight comes from water retained on and within the complete net structure.
A cage net may accumulate:
Algae
Mussels
Barnacles
Slime
Sediment
These materials add significant mass.
They also trap more water during lifting.
A net that was easy to handle when new may become much more demanding after months in service.
One part of the cage may carry much more marine growth than another.
During lifting, this creates:
Uneven weight
Panel twisting
Different border tension
Overloaded lifting points
The heaviest zone may pull one corner downward while the opposite side remains relatively light.
Underwater, hundreds or thousands of meshes help distribute force.
During lifting, the entire panel may depend on only a few connections.
For example, a large cage net may be lifted by:
Four corners
Several upper loops
One temporary lifting rope
Each connection suddenly carries a much greater share of total load.
Lifting loops concentrate load into small structural zones.
Their performance depends on:
Loop material
Diameter
Knot or splice
Border connection
Bend radius
Hardware
A strong main panel can remain intact while the loop fails first.
A thick lifting loop wrapped around a small metal ring must bend sharply.
This creates:
High contact pressure
Flattening
Abrasion
Internal fiber stress
The problem becomes more severe when the load increases suddenly.
The upper border may normally help maintain panel geometry.
During lifting, it can become a primary structural member.
If the border has:
Abrasion
Old splices
Uneven lacing
Local damage
the increased lifting load can expose these weaknesses immediately.
Corners already combine:
Vertical borders
Horizontal borders
Loops
Reinforcement
During lifting, they may also carry a large share of the net mass.
This makes them critical inspection points before any lifting operation.
A seam may perform well underwater when panel tension is distributed.
During lifting, the seam may become a major load-transfer line.
If the joining twine or adjacent mesh has aged, the seam may:
Separate
Pull neighboring knots
Tear the first mesh row beside it
The seam itself is not the only area that should be inspected.
Reinforced areas are often stronger and stiffer.
During lifting, load may move from a hard border or seam into softer main netting.
This creates a stiffness transition.
Failure may occur one or two mesh rows away from the reinforcement rather than inside it.
A net is not always lifted smoothly.
Possible events include:
Crane acceleration
Winch jerking
Wave movement
Rope slack suddenly becoming tight
These create short-duration peak forces.
A structure that tolerates steady load may fail under a sudden shock.
If lifting is performed while the cage moves with waves, the suspended net may move vertically.
The lifting rope can repeatedly:
Tighten
Relax
Snap tight again
This cyclic loading increases stress on connections.
Sometimes one side of the cage is raised first.
The remaining net hangs from a small number of points.
This can create severe local tension.
A gradual, balanced lifting method is usually structurally safer than pulling one corner far ahead of the others.
Folded netting can form pockets.
Water may remain trapped temporarily.
This creates localized downward loads.
A lifting point near the pocket may suddenly carry much more force than expected.
The net may contain:
Seaweed
Wood
Plastic
Fishing gear
Sediment
These materials may not be visible before lifting.
Once the net rises, they can collect in folds and increase local load.
The bottom section often accumulates:
Sediment
Shells
Feed residue
Fouling
When the cage is lifted, this material moves toward the lowest hanging area.
The bottom panel can therefore become a concentrated load zone.
If heavy sinkers remain connected while the net is raised, the lifting system may carry both:
Net mass
Sinker load
This can greatly increase border and loop tension.
The lifting procedure should account for the actual sinker configuration.
Removing ballast from one side first can leave the opposite side heavily loaded.
This may create:
Diagonal tension
Panel twisting
Corner overload
Balanced preparation matters before the net leaves the water.
A twine worn against a frame may still survive normal underwater loading.
During lifting, the same section suddenly carries much greater tension.
The weakened area then breaks.
The lifting event may be the immediate cause, but previous abrasion is the underlying damage.
Upper borders and loops may experience:
Sunlight
Wave action
Wet-dry cycling
Frequent handling
These areas are also commonly used for lifting.
Their remaining strength may be lower than when the net was new.
A repaired area may be:
Stiffer
Heavier
Stronger than nearby old mesh
During lifting, force may bypass the patch and concentrate beside it.
Repeatedly repaired panels deserve extra inspection before handling.
Not every attachment point is designed to carry the entire panel weight.
Using ordinary installation loops as lifting eyes can overload them.
The net design should clearly distinguish between:
Installation attachments
Structural lifting points
where applicable.
Loops may differ in:
Wear
Length
Knot condition
Hardware contact
UV exposure
Even if they were identical when new, service conditions can make them different later.
Inspect each lifting point.
During early lifting, observe whether:
One rope becomes tight first
One corner rises faster
One side remains slack
The panel twists
These are signs of uneven load sharing.
Correcting the imbalance early can prevent damage.
A deep fold full of:
Water
Fouling
Debris
can create severe concentrated load.
Redistribute or drain the section according to safe operating procedures rather than continuing to increase tension.
High-risk areas include:
Upper borders
Corners
Attachment loops
Seams
Previous repairs
Hardware-contact zones
Look for:
Fuzzing
Flattening
Cuts
Loose knots
Corrosion damage
Abrasion
A pre-lift inspection is often more useful than discovering damage after failure.
Where operationally appropriate, reducing heavy fouling before full lifting can lower:
Net mass
Retained water
Hydrodynamic resistance
However, cleaning must not damage the net itself.
Distributing lifting force across more suitable points can reduce concentration.
The goal is to spread load through the structure instead of forcing a few loops or corners to carry everything.
Any lifting arrangement should follow the engineered net and cage design.
Smooth lifting helps reduce sudden peak loads.
Avoid unnecessary:
Jerking
Rapid acceleration
Slack-to-tight impacts
Controlled motion gives the structure time to redistribute load.
Watch for:
Sudden straightening
Strong local tension
Knot movement
Lacing distortion
These can indicate that one structural path is becoming overloaded.
Lifting can create damage without immediate rupture.
After handling, inspect for:
New fuzzing
Flattening
Stretched mesh
Loose seams
Damaged loops
A successful lift does not mean nothing changed.
If the same corner or lifting point repeatedly requires repair, the issue may be systemic.
Possible causes include:
Poor lifting geometry
Inadequate reinforcement
Small hardware
Uneven load distribution
Repeated patching alone may not solve the problem.
Before lifting:
✔ Check fouling level
✔ Estimate wet handling load
✔ Inspect lifting points
✔ Check attachment loops
✔ Inspect borders
✔ Inspect corners
✔ Check seams
✔ Review previous repairs
✔ Check sinker configuration
✔ Remove trapped debris where practical
During lifting:
✔ Lift gradually
✔ Keep load balanced
✔ Watch for twisting
✔ Monitor tight and slack lifting lines
✔ Avoid shock loading
✔ Watch for heavy water pockets
✔ Monitor border tension
After lifting:
✔ Inspect loops again
✔ Check border damage
✔ Look for new mesh distortion
✔ Inspect seams
✔ Record new abrasion
✔ Document failed or overloaded zones
Fish cage nets can survive normal underwater operation but fail during lifting because the structural conditions change dramatically.
The major reasons include:
Loss of buoyant support
Wet retained water
Heavy biofouling
Concentrated lifting points
Dynamic shock loads
Uneven sinkers
Old abrasion
Weak loops, borders, seams, or corners
The key principle is:
The Net May Be Strong Enough for Its Underwater Operating Load but Not for an Uncontrolled Lifting Load Concentrated Through a Few Connections.
Reliable lifting preparation combines:
Pre-Lift Inspection + Fouling Assessment + Balanced Load Sharing + Suitable Lifting Points + Controlled Motion + Post-Lift Inspection
At PL Fishery, we manufacture PE fishing nets, fish cage panels, aquaculture netting, reinforced borders, attachment loops, custom seams, repair mesh, repair twine, marine ropes, chicken nets, and customized net products.
To purchase or customize fish cage netting, send PL Fishery your mesh size, twine construction, cage dimensions, border design, attachment and lifting-point requirements, sinker system, expected fouling conditions, handling method, and inspection requirements so our factory can prepare a measurable production specification.https://plfishery.com/